You are here

North Main Street

Anderson, SC
  • Advanced four (4) soil borings using a 4' macro core sampler at an angle of 22 1⁄2 degrees to a depth of
    16' bgs.
  • Collect four (4) groundwater samples using the SP16 groundwater sampling system in depths ranging from 30' to 50' bgs.
  • Drilling and sampling equipment was decontaminated between all borings.
  • All boreholes were grouted upon completion of drilling.
Customer: 